Discover More About Hipot Testers, Dielectric Strength Tests And Their Similarities And Dissimilarities

By Carl Hughes


Dielectric Strength or hipot test procedure is conducted by generating high voltage power between wire tested to the ground, most likely locomotive chassis. When overloaded current leaks or when an arc transpires, test fall short. Insulation Resistance measuring usually presents numerical values on resistance insulation indication. Facts on hipot testers measuring work are discussed.

High Pot can be AC or DC and done periodically, or at production line end, etc. Stress test result typically shows Pass Fail based on leakage current. For some systems, this may prove dangerous. Testing Medium Voltage Cable may also prove risky.

Dielectric strength presents maximum electrical field that pure material may withstand underneath ideal setting without tearing down or without experiencing failure with its insulating properties. Theoretical dielectric strength is material intrinsic property on bulk material and independent configuration material or electrodes with which field is put to use. This inherent dielectric withstand corresponds what is being measured using untouched materials under controlled laboratory settings.

At breakdown, electrical fields free bounded electrons. If applied electrical fields are sufficiently high, freed electrons from surrounding radiation might accelerate with velocities which could liberate further electrons during neutral atom molecule collision in a course termed avalanche breakdown. Avalanche Breakdowns take place somewhat quickly, in nanoseconds normally, resulting into an electrically conducive path structure and disrupting electron release throughout an object. For concrete materials, avalanche breakdown event rigorously debase, even demolish said materials insulating potential.

With respect to insulations and dielectric testings differences, none exists. Contrast between insulation and di electric testing does not matter. Dielectric quality basically demonstrates how well an insulator is. About testing, frequency test ought to be controlled by what voltage insulating substance should expect amid its functional period. Which implies you ought keep from DC quality testing aspects that will be utilized for AC 50 or 60 Hertz applications.

Whilst they are only two particular and altogether different techniques, these terms are irresponsibly tossed around reciprocally in trade. So you cannot without much stretch depend on those names precisely portraying what is being examined closely by way test was done. For instance, in Practice manual Dielectric Tests, wherein Di electric Tests within definition is mix of HiPot tests Insulation Resistance tests.

Though, commonly, HiPot analyzer being utilized for Di electric Quality test would satisfy usage towards Insulation Resistance analyzation. Particular terminology utilization would truly rely upon trade you are working, managing. In the event that it truly matters, you have to read given methodology label itself.

An Insulation Resistance tests would always show DC. Di electric Strength tests would usually AC but could be DC. If one see if one other could go through elimination as they investigate similar things, electrical experiments were done before. Conclusion was that they are both needed as they provide different data as their results.

An emphasis on these tests interchangeability would trivial because, at the end of the day, most insulated materials go through both as it unwise generally to pigeon hole your substance product into using only one frequency, electrical transmission when most cases it will work for both assuming they have same amount. Using 48v DC system, generally using materials with secondary rating around 600v ac should suffice. Ultimately as long as one does not fail hipot, everyones happy regardless of insulated matter used.